Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 115069.015 - Employee Develops Edema From Foot Fracture And Later Dies

Accident: 115069.015 -- Report ID: 0317900 -- Event Date: 04/01/2019
InspectionOpen DateSICEstablishment Name
1389853.01504/02/2019Artsquest
At 6:38 p.m. on April 1, 2019, an employee was disassembling a stage when its su pport legs fell out of the leg receivers. As a result, the stage collapsed on th e employee's foot, fracturing it. The employee developed a blood edema three we eks later and died.
Keywords: collapse, foot, fracture, struck by
Employee # Inspection Age Sex Degree Nature
1 1389853.015 43 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close