Accident: 114700.015 - Employee'S Finger Is Amputated By Radial Arm Saw
Accident: 114700.015 -- Report ID: 0626300 -- Event Date: 01/18/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1373749.015 | 01/23/2019 | First Co. | |||||
At 6:20 a.m. on January 18, 2019, Employee # 1 was operating a radial arm saw that is mounted to a table. The saw was used to cut wood for building pallets. The employee had just turned off the saw and ran his hand across the table as he was turning his body. His finger came into contact with the A part of the saw blade, which not covered by the guard, and was amputated. The entry states he was not hospitalized, but he likely was. | |||||||
Keywords:
saw, amputated, finger, hand, amputation, guard, blade
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | ||
1 | 1373749.015 | 22 | M | Hospitalized injury | Amputation |