Accident Report Detail
Accident: 114377.015 - Employee Is Struck And Killed By Falling Anti-Two-Block Devi
Accident: 114377.015 -- Report ID: 0636900 -- Event Date: 03/12/2019 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1384573.015 | 03/12/2019 | Ats Drilling, Inc. | |||||
At 12:15 a.m. on March 12, 2019, Employee #1 and a coworker, employed by a drilling company, were engaged in crane operations at a bridge construction site. The coworker was operating the crane. Employee #1 was signaling the coworker to lower the crane's auxiliary line so the rigging could be removed. The crane's anti-two-block device fell from the top of the crane and struck Employee #1 in the head. He sustained a fractured skull and was killed. | |||||||
Keywords:
struck by, construction, falling object, rigging, fracture, crane block, crane, signalman, skull, two-blocking
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Bridge | New project or new addition | X | |||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1384573.015 | 28 | M | Fatality | Fracture | Construction laborers |