Accident: 114162.015 - Employee Amputates Tip Of Finger While Replacing Roller On C

Accident: 114162.015 -- Report ID: 0524530 -- Event Date: 02/28/2019
InspectionOpen DateSICEstablishment Name
1382611.01503/05/2019Gbc Metals Llc Dba Olin Brass
At 8:30 p.m. on February 28, 2019, Employee #1 was replacing a roller on conveyo r wile attempting to guide the shaft bearing into position on the conveyor. The roller shaft was being lifted by an overhead hoist using remote controls. This hoist was being operated by the employee. Just prior to the injury, the employe e had his finger in the shaft hole to guide the hex head shaft into place. The employee bumped the remote opening controls of the overhead hoist, causing the s haft and roller to move amputating the finger tip. The employee was hospitalized .
Keywords: amputated, amputation, conveyor, finger, hoisting mechanism, roller conveyor
Employee # Inspection Age Sex Degree Nature Occupation
1 1382611.015 62 M Hospitalized injury Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.