Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 113780.015 - Employee Is Killed When Crushed By Trailer

Accident: 113780.015 -- Report ID: 0627510 -- Event Date: 02/18/2019
InspectionOpen DateSICEstablishment Name
1379789.01502/19/2019Tokai Carbon Cb, Ltd.
At 9:30 a.m. on February 18, 2019, an employee was standing in a work area near a vehicle. The employee was later found crushed beneath the rear tires of a trai ler. He was killed.
Keywords: crushed, run over, trailer, vehicle
Employee # Inspection Age Sex Degree Nature
1 1379789.015 20 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close