Accident Report Detail
Accident: 112356.015 - Employee Fractures Wrist While Sending Pig Through Pipe
Accident: 112356.015 -- Report ID: 0317500 -- Event Date: 12/10/2018 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1365460.015 | 12/10/2018 | Precision Pipeline Llc | |||||
At 1:15 a.m. on December 10, 2018, Employee # 1, was standing next to the pipe. The pig had no frontal head pressure to slow it down because a relief valve was left open. He was struck by the steel door at the end of the pipe. He suffered broken bones in his wrist and was hospitalized. | |||||||
Keywords:
pipe, open valve, fracture, struck by, safety relief valve, wrist
| |||||||
End Use | Proj Type | Proj Cost | Stories | NonBldgHt | Fatality | ||
Pipeline | New project or new addition | 0 | 0 | ||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1365460.015 | 24 | M | Hospitalized injury | Fracture | Welders and cutters |