Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 111590.015 - Worker Amputates Left Middle Finger Tip While Operating Conv

Accident: 111590.015 -- Report ID: 0551702 -- Event Date: 12/01/2018
InspectionOpen DateSICEstablishment Name
1364404.01512/06/2018University Of Il - Urbana
At 5:30 a.m. on December 1, 2018, Employee #1 was starting the conveyor belt to feed animals. The belt was slipping on the conveyor due to damp conditions and p oor maintenance. The employee attempted to overcome the friction by manually tur ning the belt on the conveyor. This process involved removing a guard. The emplo yee's left middle finger was caught in a pinch point, resulting in an amputation . The employee was hospitalized.
Keywords: amputation, caught in, conveyor, conveyor belt, finger, lockout/tagout, machine guarding, nip point
Employee # Inspection Age Sex Degree Nature Occupation
1 1364404.015 19 M Non Hospitalized injury Farm workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close