Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 111218.015 - Employee Is Struck By Dump Truck And Is Killed

Accident: 111218.015 -- Report ID: 0317900 -- Event Date: 11/13/2018
InspectionOpen DateSICEstablishment Name
1361872.01511/13/2018Mclane Company, Inc.
At 8:00 a.m. on November 13, 2018, an employee was walking into work from the pa rking lot. He walk into the path of a truck and was run over by a dump truck. Th e employee was killed from his injuries.
Keywords: dump truck, run over, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 1361872.015 44 M Fatality Driver-sales workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close