Accident: 110304.015 - Employee Incurs Vascular Contusion When Pressurized Water Ma

Accident: 110304.015 -- Report ID: 0950615 -- Event Date: 05/23/2018
InspectionOpen DateSICEstablishment Name
1318848.01505/23/2018Sanco Pipelines, Incorporated
At 11:00 a.m. on May 23, 2018, an employee was attempting to charge a twelve inc h water main. The employee did not properly secure the Mega Lug twelve inch cap on the end of the water main, which blew off the main when the line charged and struck the employee in an unspecified portion of his body. The employee received a vascular contusion (crushed artery) injury and was hospitalized.
Keywords: artery, contusion, crushed, struck against, water pipe
Employee # Inspection Age Sex Degree Nature Occupation
1 1318848.015 45 M Hospitalized injury Excavating and loading machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.