Accident: 109017.015 - Employee Lacerates Wrist And Forearm From Ice Saw

Accident: 109017.015 -- Report ID: 0552652 -- Event Date: 09/01/2018
InspectionOpen DateSICEstablishment Name
1344267.01509/11/2018Continental Carbonic Products Inc
At 8:00 a.m. on September 1, 2018, Employee #1 was assisting the block line in end of shift clean-up and attempted to remove a chunk of dry ice from the gang saw. The machine was shut down via the E-Stop, but unpowered saw blades (6) continued to rotate due to residual kinetic energy. The employee activated the 2-handed controls which raised the pneumatic controlled guard and allowed access to the blades. The employee suffered lacerations to the left wrist and forearm, and significant tendon & muscle damage, which required surgery. The employee was hospitalized.
Keywords: saw, forearm, guard, laceration, lockout/tagout, blade, tendon, wrist
Employee # Inspection Age Sex Degree Nature Occupation
1 1344267.015 21 M Hospitalized injury Cut/Laceration Sawing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close