At 8:40 p.m. on August 28, 2018, Employee #1, employed by a store interior design, manufacture, and installation company, was operating the Cincinnati PB-4 hydraulic press brake to form sheet metal parts that had two sequential bendings. The parts were approximately 3 inches wide and 48 inches long. The machine was protected by a light curtain to prevent proximity to the die gap which could be as wide as 7 inches. The mute point was typically set at 0.25 inches. Employee #1 increased the mute point on the downward stroke to increase working speed. His left thumb was partially crushed and amputated, with loss of seventy five percent of the nail. He was hospitalized.
Keywords: thumb, crushed, finger, hydraulic press, hand, die, bending machine, amputated
Employee # Inspection Age Sex Degree Nature Occupation
1 1344608.015 35 M Non Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close