Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 108577.015 - Employee Suffers Seizure

Accident: 108577.015 -- Report ID: 0950647 -- Event Date: 07/20/2018
InspectionOpen DateSICEstablishment Name
1338571.01508/16/2018Stop N Recycle
At 1:27 p.m. on July 20, 2018, Employee #1 was bringing in bottles for recycling . Afterwards, the employee went next door to the sitting area to eat. While eati ng, the employee vomited and complained he was not feeling well and suffered a s eizure.
Keywords: vomit
Employee # Inspection Age Sex Degree Nature
1 1338571.015 60 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close