Accident: 107585.015 - Employee Amputates Fingers From Failure To Lockout Machine
Accident: 107585.015 -- Report ID: 0418600 -- Event Date: 06/08/2018 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1332321.015 | 06/19/2018 | Miller & Company, Inc. | |||||
At 2:20 p.m. on June 8, 2018, an employee reached inside the side matcher machine to remove a piece of wood. The machine was not locked out, and the guard was removed. The employee sustained an amputation of two fingers and laceration to another from the cutting blade. | |||||||
Keywords:
unguarded, amputated, lockout/tagout, machine guarding, amputation, lockout, guard, finger
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |