Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable.
To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA).

Accident Report Detail

Accident: 106209.015 - Employee Is Injured While Operating Press Brake

Accident: 106209.015 -- Report ID: 0355111 -- Event Date: 05/03/2018
InspectionOpen DateSICEstablishment Name
1313557.01505/03/2018R W Harper And Son, Inc.
At 9:30 a.m. on May 3, 2018 an employee was working on a press brake. While the employee was bending a piece of sheet metal, he dropped it. The employee placed his hands between the press and die when he was trying to retrieve it, causing s evere lacerations to the employee's fingers.
Keywords: finger, laceration, press brake, sheet metal
Employee # Inspection Age Sex Degree Nature Occupation
1 1313557.015 21 M Hospitalized injury Sheet metal worker apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close