Accident: 102854.015 - Two Employees Killed By Concrete Barrier Landing On Them.

Accident: 102854.015 -- Report ID: 0418800 -- Event Date: 02/04/2018
InspectionOpen DateSICEstablishment Name
1293032.01502/05/2018Archer Western Construction, Llc
At 3:00 a.m. on February 4, 2018, two employees were working in a trench adjacen t to a previously poured concrete highway barrier measuring 121 feet in length w hen the soil beneath the barrier collapsed and the barrier toppled over. Both e mployees were crushed and suffered injuries from the chest down over their bodie s and were killed on-site.
Keywords: barrier guard, buried, collapse, concrete beam, crushed, highway, trench
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Highway, road, street Other   0 0 X
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 1293032.015 37 M Fatality Carpenters FallDist:
FallHt:
Cause: Traffic protection
FatCause:
2 1293032.015 33 M Fatality Carpenters FallDist:
FallHt:
Cause: Traffic protection
FatCause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.