Accident Report Detail
Accident: 102824.015 - Employee Falls During Personnel Hoisting Operation And Suffe
Accident: 102824.015 -- Report ID: 0830300 -- Event Date: 01/31/2018 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1292823.015 | 02/05/2018 | Cache Trucking, Llc | |||||
At 6:30 p.m. on January 31, 2018, an employee was being raised approximately 20 feet above the rig floor when the wire rope swivel snagged on a tubing board. When it was dislodged, the employee was jerked upward approximately 10 feet before going into a free fall. The employees fall stopped suddenly and he fractured his pelvis and lower vertebra. The employee was hospitalized. | |||||||
Keywords:
pelvis, hoistline, hoisting mechanism, vertebra, fall, fracture, hoist
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 1292823.015 | 23 | M | Hospitalized injury | Fracture | Drillers, oil well |