Accident: 102632.015 - Employee'S Finger Tip Is Amputated During Maintenance Activi

Accident: 102632.015 -- Report ID: 0524700 -- Event Date: 01/24/2018
InspectionOpen DateSICEstablishment Name
1291209.01501/30/2018Honda Of America Mfg., Inc.
At 2:40 p.m. on January 24, 2018, Employee #1 was performing maintenance activities of the metering cylinders located in the Packaging Robot cell on line #1. Employee #1 operating inside the cell, was performing an operational test of the metering cylinders escapement pins. Employee #1 was providing verbal instructions to a coworker who was manually initiating the cycle via solenoid control outside the cell. As Employee #1 was making adjustments to the float controls, his left third finger dropped between the rear plate of the escapement pin and the cylinders housing. The coworker initiated a cycle, and Employee #1's fingertip was caught between the two components. No effective form of guarding around the pinch point or isolation of pneumatic energy was in place at the time of the event. Employee #1 was hospitalized and treated for his injuries.
Keywords: unguarded, finger, maintenance, amputation, guard, caught between
Employee # Inspection Age Sex Degree Nature Occupation
1 1291209.015 58 M Hospitalized injury Amputation Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close