Accident: 102155.015 - Employee Suffers Partial Amputation Of Three Fingers

Accident: 102155.015 -- Report ID: 0751910 -- Event Date: 11/28/2017
InspectionOpen DateSICEstablishment Name
1287414.01501/10/2018Berry Global Inc Qdc
At 1:00 p.m. on November 28, 2017, Employee #1 was changing dies on the Aoki mol d. The employee was rotating the table by hand to tighten the gibes on the dies. As he reached up to stop the table from rotating, the employee's fingers entere d a hole in the table. The rotating table continued to move and three fingertips on his left hand were amputated by the casting and rotating table.
Keywords: amputated, die, finger, mold, rotating parts
Employee # Inspection Age Sex Degree Nature
1 1287414.015 30 M Non Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.