Accident Report Detail
Accident: 101510.015 - Tree Limb Falls Striking Two Employees, Resulting In One Hos
Accident: 101510.015 -- Report ID: 0522500 -- Event Date: 12/05/2017 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
1283197.015 | 12/13/2017 | Asplundh Tree Experts, Llc | |||||
At 2:00 p.m. on December 5, 2017, Employee #1 was cutting a tree with a chainsaw . Employee #2 was standing nearby the base of the tree. A foreman and an employ ee were standing in the rear danger zone of a 24 inch Diameter at Breast Height (DBH), a 78 foot tall dead Ash tree was being felled by another foreman, who was operating a chain saw. The foreman who was standing to the rear had just placed a wedge in the cut that was made by the foreman who was operating the chain saw . When the tree went over, a large branch of the dead Ash tree (43 foot long, 11 inch diameter) struck an adjacent 12 inch DBH Maple tree, causing a branch of t he dead Ash tree to break off and fall. The branch fell backwards striking both of the employees in the danger zone, resulting in the long term hospitalization of the foreman. | |||||||
Keywords:
chain saw, struck by, tree trimming
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | ||
1 | 1283197.015 | 56 | M | Hospitalized injury |