Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 100939.015 - Employee Is Replacing Plug To Industrial Vacuum And Receives

Accident: 100939.015 -- Report ID: 0523400 -- Event Date: 08/15/2017
InspectionOpen DateSICEstablishment Name
1256237.01508/15/2017Badger Alloys, Inc.
On August 15, 2017, an employee was fixing a plug to an industrial vacuum. The employee connected the wrong wires and received an electrical shock. The employee suffered some electrical burns and was rendered unconscious. Hospitalization was not required.
Keywords: plug adapter, electric shock, fainted, electrical, unconsciousness, vacuum cleaner, burn
Employee # Inspection Age Sex Degree Nature
1 1256237.015 49 M Hospitalized injury Electric Shock

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close