Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 100464.015 - Employee Sustains Burns From Flying Molten Metal When Scrap

Accident: 100464.015 -- Report ID: 0552652 -- Event Date: 05/04/2017
InspectionOpen DateSICEstablishment Name
1265435.01510/05/2017Fritz Enterprises Inc Dba Fritz Products Inc
At 2:00 p.m. on May 4, 2017, an employee was staging scrap metal material to be put into a melting furnace. The employee dumped the material into the melting fu rnace from a charge box which contained moisture. The metal exploded out of the furnace toward the employee. The employee was not wearing required personal prot ective equipment. The employee sustained burns to skin from contact with the mol ten metal.
Keywords: burn, explosion, furnace, heat, ppe, protective clothing, scrap metal, skin, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 1265435.015 30 M Hospitalized injury Molding and casting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.