Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 100388.015 - Employee Suffers Neck Laceration When Slick Line Parts

Accident: 100388.015 -- Report ID: 0830500 -- Event Date: 10/30/2017
InspectionOpen DateSICEstablishment Name
1274510.01511/01/2017Summit Oilfield Services
At 12:00 p.m. on October 30, 2017, Employee #1 was using a slick line oil operat ion to retrieve tools. The slick line parted, and the employee was struck in the neck. The employee sustained a laceration to his neck and was hospitalized for treatment.
Keywords: blowout--oil well, digger/derrick, kick back, laceration, neck, oil well drilling/servicing, struck by
Employee # Inspection Age Sex Degree Nature Occupation
1 1274510.015 60 M Hospitalized injury Engineering technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close