Accident: 1001460 - 8 Employees Exposed To Mists Of Cutting Oil

Accident: 1001460 -- Report ID: 0751910 -- Event Date: 09/23/1987
InspectionOpen DateSICEstablishment Name
10420168609/23/19873633Wci - Laundry Div./Jefferson, Ia
EIGHT MACHINE OPERATORS WERE GRINDING, THREADING AND TAPPING HOLES FOR WASHING MACHINE PARTS IN MACHINE AND ASSEMBLY DEPARTMENTS A, B AND D. THE MACHINES THE EMPLOYEES WERE OPERATING INCLUDED: CINCINNATI MILICRON CENTERLESS GRINDERS, AUTOMATIC SCREW MACHINES AND MULTI-HEAD DRILLS. THE MACHINED PARTS ARE FLOODED WITH CUTTING OIL (MINERAL SPIRITS). THE TRADENAME "HOCUT 757" IS A TYPICALLY USED CUTTING OIL. IT CONTAINS P-CHLORO M-CRESOL AS A BIOCIDE. AT THE POINT OF USE (20:1 DILUTION), A 0.1% TO 0.5% OIL MIST IS GENERATED. CONCENTRATIONS OF 2.1 MG/M3, 1.2MG/M3 AND 1.8 MG/M3 ARE GENERATED AT THE CENTERLESS GRINDERS DUE TO THE SHEARING ACTION OF THE HIGH SPEED (1250 PPM) GRINDING STONES. FOUR EMPLOYEES EXPERIENCED RESPIRATORY PROBLEMS SUCH AS COUGHING, PHLEGM, SORE THROAT, TIGHTNESS OF CHEST AND BRONCHITIS. ONE OF THESE EMPLOYEES EXPERIENCED VASCULAR PROBLEMS SUCH AS TACHYCARDIA AND VENTRICULAR ARRYTHMIA. FOUR OTHER EMPLOYEES CONTRACTED DERMATITIS. THE PROBLEMS WERE CAUSED BY THE LACK OF SPLASH GUARDS AND THE FAILURE TO USE MIST ELIMINATION PROCEDURES.
Keywords: threading machine, dermatitis, work rules, inhalation, respiratory tract, chemical vapor, toxic fumes, grinding machine, unguarded, cough
Employee # Inspection Age Sex Degree Nature Occupation
1 104201686 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 104201686 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
3 104201686 Non Hospitalized injury Dermatitis Occupation not reported
4 104201686 Non Hospitalized injury Dermatitis Occupation not reported
5 104201686 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
6 104201686 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
7 104201686 Non Hospitalized injury Dermatitis Occupation not reported
8 104201686 Non Hospitalized injury Dermatitis Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.