Violation Detail
Standard Cited: 19260451 B01 General requirements.
Inspection Nr: 998275.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 10/16/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 11/10/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/16/2014 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) Front side, new residential construction located at 3888 Thackary Drive, Powder Springs, GA 30127: Employees were exposed to falls of approximately 12-feet, 11-inches to the lower level while engaged in brick installation work on a tubular welded scaffold platform which was not fully planked.