Violation Detail
Standard Cited: 19260452 J02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 997540.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 10/14/2014 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/06/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0625400
Contest Date:
Final Order: 11/07/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/06/2014 | $0.00 | 10/14/2014 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about October 01, 2014, the pump jack scaffold system set up on the west side of the property under construction was supported by lumber instead of components approved by the manufacturer, exposing employees to the hazards of falls in the event of scaffold collapse or failure.