Violation Detail
Standard Cited: 19100146 C05 II B Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 991592.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/23/2014
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 12/15/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0626700
Contest Date: 01/05/2015
Final Order: 09/25/2016
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 09/25/2016 | $0.00 | 12/23/2014 | Serious | |
| Penalty | C: Contested | 01/05/2015 | $2,800.00 | 12/23/2014 | Serious | |
| Penalty | Z: Issued | 12/15/2014 | $2,800.00 | 12/23/2014 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.146(c)(5)(ii)(B): When an entrance cover was removed, the opening was not promptly guarded by a railing, temporary cover, or other temporary barrier that would prevent an accidental fall through the opening and that would protect each employees from falling through the opening: a) At the worksite, on August 13, 2014, the manhole was not guarded by a barrier to prevent employees from falling into the confined space.