Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 989416.015
Citation: 01002
Citation Type: Serious
Abatement Date: 10/20/2014 2
Initial Penalty: $4,900.00
Current Penalty: $3,920.00
Issuance Date: 10/01/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0830300
Contest Date:
Final Order: 10/31/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/31/2014 | $3,920.00 | 10/20/2014 | Serious | |
| Penalty | Z: Issued | 10/01/2014 | $4,900.00 | 10/20/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) For an employee who suffered fatal crushing injuries while performing maintenance on a John Deere 644K loader at or near 8116 61st Street NW Lot Eight in Stanley, North Dakota.