Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 988820.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,500.00
Current Penalty: $2,100.00
Issuance Date: 08/26/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 09/03/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/03/2014 | $2,100.00 | Serious | ||
Penalty | Z: Issued | 08/26/2014 | $3,500.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. At the establishment, employees were exposed to a caught in hazard, in that, while using the Rockwell Model 11 drill press the spindle pulleys were not guarded during operation, on or about 08/07/2014