Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 983013.015
Citation: 01004
Citation Type: Serious
Abatement Date: 01/25/2015 2
Initial Penalty: $7,000.00
Current Penalty: $6,666.00
Issuance Date: 12/22/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0625500
Contest Date:
Final Order: 01/12/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/12/2015 | $6,666.00 | 01/25/2015 | Serious | |
| Penalty | Z: Issued | 12/22/2014 | $7,000.00 | 01/25/2015 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: Bldg 151, Room 1.310: On or about June 25, 2014 employees were exposed to a struck by hazard while removing a viewing port on a constant volume combustion chamber without depressurizing the system to isolate the stored energy.
Translate