Violation Detail
Standard Cited: 19100178 G02 Powered industrial trucks.
Inspection Nr: 97716.015
Citation: 01001
Citation Type: Serious
Abatement Date: 01/26/2012 2
Initial Penalty: $4,500.00
Current Penalty: $2,700.00
Issuance Date: 12/27/2011
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 01/18/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/18/2012 | $2,700.00 | 01/26/2012 | Serious | |
| Penalty | Z: Issued | 12/27/2011 | $4,500.00 | 01/26/2012 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.178(g)(2): Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries. a) At the Yenkin-Majestic Paint Corporation in Columbus, Ohio, the warehouse had a Hobart Battery Charger (model # 865-c3-18, Serial # 389cs09135) that was sitting on a pallet on the floor, within two to three feet of where the forklifts drive and park on a daily basis, and was not protected from damage from the forklifts.
Translate