Violation Detail
Standard Cited: 19261417 O03 I
Inspection Nr: 960040.015
Citation: 01009
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/16/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 06/25/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/25/2014 | $0.00 | Serious | ||
| Penalty | Z: Issued | 06/16/2014 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 009 Hazard:
29 CFR 1926.1417(o)(3)(i): The weight of the load was not determined from a source recognized by the industry (such as the loads manufacturer), or by a calculation method recognized by the industry (such as calculating a steel beam from measured dimensions and a known per foot weight), or by other equally reliable means: (a) Construction Site - On or about February 22, 2014 the weight of the concrete septic tank was not determined prior to elevating and moving the load with truck crane.
Translate