Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 954539.015
Citation: 01004B
Citation Type: Serious
Abatement Date: 06/16/2014 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/28/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 06/11/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/11/2014 | $0.00 | 06/16/2014 | Serious | |
Penalty | Z: Issued | 05/28/2014 | $0.00 | 06/16/2014 | Serious |
Text For Citation: 01 Item/Group: 004B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) The employer did not develop lockout/tagout procedures to control hazardous energy when performing maintenance and/or setup work (e.g. changing plates in the Thermatron heat seal presses).