Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 952785.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 06/04/2014 2
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 04/21/2014
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0627100
Contest Date: 05/16/2014
Final Order: 10/08/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/08/2014 | $1,400.00 | 06/04/2014 | Serious | |
| Penalty | C: Contested | 05/20/2014 | $2,800.00 | 06/04/2014 | Serious | |
| Penalty | Z: Issued | 04/21/2014 | $2,800.00 | 06/04/2014 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about November 27, 2013, at the job site located on Sugar Loaf Tower Road near Calico Rock, Arkansas, the employer did not have in place an energy control program to ensure that employees performing maintenance on a Timberjack Model 840 tree feller/buncher were not exposed to the release of stored energy. An employee was replacing a hydraulic hose on the equipment with the cutting head elevated approximately 5 feet above the ground. Once the hose was removed, the cutting head fell on another employee working on the equipment. This created conditions which exposed the employee to the hazard of being crushed by the falling head assembly.