Violation Detail
Standard Cited: 19280051 B02 I A Roll-over protective structures (ROPS) for tractors used in agricultural op...
Inspection Nr: 942973.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 12/18/2013
Initial Penalty: $4,500.00
Current Penalty: $2,500.00
Issuance Date: 10/08/2013
Nr Instances: 2
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 1032500
Contest Date:
Final Order: 10/24/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/24/2013 | $2,500.00 | 12/18/2013 | Serious | |
| Penalty | Z: Issued | 10/08/2013 | $4,500.00 | 12/18/2013 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1928.51(b)(2)(i)(A): Where ROPS were required by this section, the employer did not provide each tractor with a seatbelt which meets the requirements of this paragraph: (a) On or about October 1, 2013, and at times prior thereto, the employer did not have available seatbelts for employees use on the Steiger CU 360 Agricultural. (b) On or about October 1, 2013, and at times prior thereto, the employer did not have available seatbelts for employees use on the Case International 9280. Note: Abatement certification IS required for this item.