Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 940711.015
Citation: 01004
Citation Type: Serious
Abatement Date: 03/20/2014 2
Initial Penalty: $2,000.00
Current Penalty: $1,400.00
Issuance Date: 02/12/2014
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): C
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 03/03/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/03/2014 | $1,400.00 | 03/20/2014 | Serious | |
Penalty | Z: Issued | 02/12/2014 | $2,000.00 | 03/20/2014 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about August 12, 2013, in the main production are, the belt and pulley system providing power to the hydraulic bearing press was not effectively guarded. The guard in place was not affixed and contained openings.