Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 930829.015
Citation: 02008
Citation Type: Willful
Abatement Date: 03/11/2014 2
Initial Penalty: $70,000.00
Current Penalty: $70,000.00
Issuance Date: 02/12/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0419700
Contest Date: 03/05/2014
Final Order: 07/10/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 07/10/2015 | $70,000.00 | 03/11/2014 | Willful | |
| Penalty | C: Contested | 12/19/2014 | $70,000.00 | 03/11/2014 | Willful | |
| Penalty | Z: Issued | 02/12/2014 | $70,000.00 | 03/11/2014 | Willful |
Text For Citation: 02 Item/Group: 008 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by the point of operation and moving parts: a. On or about August 16, 2013, in the east wire bay, the turn table of Tuerema wire draw machine was not guarded, exposing employees to the being struck-by or caught-in the moving parts of the machine. b. On or about August 16, 2013, in the east wire bay, the spooler of the Tuerema wire draw machine was not guarded, exposing employees to the being struck-by or caught-in the moving parts of the machine.