Standard Cited: 19100146 D04 Permit-required confined spaces
Inspection Nr: 925845.015
Citation: 01009A
Citation Type: Serious
Abatement Date: 12/25/2013 2
Initial Penalty: $6,300.00
Current Penalty: $4,000.00
Issuance Date: 11/20/2013
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0522000
Contest Date: 12/18/2013
Final Order: 04/30/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 04/30/2014 | $4,000.00 | 12/25/2013 | Serious | |
| Penalty | C: Contested | 12/18/2013 | $6,300.00 | 12/25/2013 | Serious | |
| Penalty | Z: Issued | 11/20/2013 | $6,300.00 | 12/25/2013 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.146(d)(4): The employer did not provide the equipment specified in paragraphs (d)(4)(i)-(d)(4)(ix) of this section at no cost to employees, did not maintain that equipment properly, and/or did not ensure that employees use that equipment properly: (a) On or about August 6, 2013, and (b) On or about June 11, 2013: the employer did not provide and ensure the usage of the following equipment: 1. Testing and monitoring equipment; 2. Communication equipment; 3. Rescue equipment such as, but not limited to, full body harness, retrieval line and a mechanical device/winch to assist in retrieval of personnel from vertical permit spaces more than 5 feet deep.