Violation Detail
Standard Cited: 19100134 D01 II Respiratory Protection.
Inspection Nr: 924045.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 11/26/2013
Nr Instances: 3
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0936100
Contest Date:
Final Order: 12/19/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/19/2013 | $2,800.00 | Serious | ||
| Penalty | Z: Issued | 11/26/2013 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.134(d)(1)(ii): The employer did not use a NIOSH-certified respirator in compliance with the conditions of its certification: Establishment Wide: On July 30, 2013, and at times prior thereto, the employer did not prevent employees from modifying their supplied air respirators by installing an air-flow control valve, not approved by the manufacturer, thereby negating the respirator certification. This standard is incorporated into shipyard employment by 29 CFR 1915.154.