Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 910443.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,000.00
Current Penalty: $2,100.00
Issuance Date: 07/10/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 1
Report ID: 0317500
Contest Date:
Final Order: 07/29/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/29/2013 | $2,100.00 | Serious | ||
| Penalty | Z: Issued | 07/10/2013 | $3,000.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. a) Jobsite, 240 Center Street, Meyersdale, PA: On or before 06/04/13, employees working from a pump jack scaffold approximately 9 feet from the ground level were not provided a means of access. An employee climbed 5 feet from the working surface of the scaffold into a building window to exit the scaffold.
Translate