Violation Detail
Standard Cited: 19100184 E01 Slings.
Inspection Nr: 896712.015
Citation: 01003
Citation Type: Serious
Abatement Date: 10/03/2013 2
Initial Penalty: $6,000.00
Current Penalty: $6,000.00
Issuance Date: 09/09/2013
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0627500
Contest Date:
Final Order: 10/02/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/09/2013 | $6,000.00 | 10/03/2013 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity: Rig#3 Lease: Mitchell 8014 Orla, TX, Reeves County: On or about March 18, 2013, employees at a rig floor and substructure were working with a sling that was not tagged with rated capacity. This condition exposed employees to potential struck-by hazards.
Translate