Violation Detail
Standard Cited: 19100333 B02 IV B Selection and use of work practices
Inspection Nr: 893833.015
Citation: 01012B
Citation Type: Serious
Abatement Date: 04/19/2014 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/06/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date: 06/18/2013
Final Order: 03/20/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 03/20/2014 | $0.00 | 04/19/2014 | Serious | |
| Penalty | C: Contested | 07/01/2013 | $0.00 | 07/24/2013 | Serious | |
| Penalty | Z: Issued | 06/06/2013 | $0.00 | 07/24/2013 | Serious |
Text For Citation: 01 Item/Group: 012B Hazard:
29 CFR 1910.333(b)(2)(iv)(B): A qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts are deenergized: Location: The south part of bay 1 at Davis Tool and Die, 888 Bolger Ct., Fenton, Missouri 63026. On or about March 6, 2013 a maintenance worker performing repair activities on a 480 volt, three (3) phase Delta W.S. Rockwell electric oven, s/n S966, had no testing equipment with him to verify the parts were deenergized prior to working on the equipment. The worker was electrocuted after contacting energized electrical parts of the oven.