Violation Detail
Standard Cited: 19100146 K01 I Permit-required confined spaces
Inspection Nr: 765141.015
Citation: 01020
Citation Type: Serious
Abatement Date: 05/30/2013 2
Initial Penalty: $2,800.00
Current Penalty: $2,240.00
Issuance Date: 05/09/2013
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 05/31/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/31/2013 | $2,240.00 | 05/30/2013 | Serious | |
| Penalty | Z: Issued | 05/09/2013 | $2,800.00 | 05/30/2013 | Serious |
Text For Citation: 01 Item/Group: 020 Hazard:
29 CFR 1910.146(k)(1)(i): When designating rescue and emergency services pursuant to paragraph (d)(9), the employer did not evaluate the prospective rescuer's ability to respond to a rescue summons in a timely manner, considering the hazards identified: a) On or about November 29, 2012, Phoenix Industrial Cleaning, Inc., selected "911" as their designated rescue and emergency service for a permit space entry. The employer did not ensure they evaluated the ability of this service to respond to a rescue summons in a timely manner prior to employee(s) entry into a 6,000 gallon 16 foot vertical chemical storage tank at Sunnyside Corporation in Wheeling, Illinois. This tank was last used by Sunnyside Corporation to store methylene chloride.