Violation Detail
Standard Cited: 19100146 F10 Permit-required confined spaces
Inspection Nr: 765141.015
Citation: 01018
Citation Type: Serious
Abatement Date: 05/30/2013 2
Initial Penalty: $2,800.00
Current Penalty: $2,240.00
Issuance Date: 05/09/2013
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 05/31/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/31/2013 | $2,240.00 | 05/30/2013 | Serious | |
| Penalty | Z: Issued | 05/09/2013 | $2,800.00 | 05/30/2013 | Serious |
Text For Citation: 01 Item/Group: 018 Hazard:
29 CFR 1910.146(f)(10): The entry permit that documents compliance and authorizes entry to a permit space did not identify the results of initial and periodic tests performed under 29 CFR 1910.146(d)(5), accompanied by the names or initials of the testers and by indication of when the tests were performed: a) On or about November 29, 2012, Phoenix Industrial Cleaning, Inc. did not ensure the results of initial and periodic tests required under 29 CFR 1910.146(d)(5) were documented on the confined space entry permit, prior to and during employee(s) entry into a 6,000 gallon 16 foot vertical chemical storage tank at Sunnyside Corporation in Wheeling, Illinois. This tank was last used by Sunnyside Corporation to store methylene chloride.