Violation Detail
Standard Cited: 19100134 D01 III Respiratory Protection.
Inspection Nr: 765141.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/09/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 05/31/2013
Emphasis:
Substance: 1730
Substance: X100
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/31/2013 | $0.00 | Serious | ||
| Penalty | Z: Issued | 05/09/2013 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) On or about November 29, 2012, Phoenix Industrial Cleaning, Inc. did not identify and evaluate the respiratory hazard(s) prior to employee(s) entry into a 6,000 gallon 16 foot vertical chemical storage tank at Sunnyside Corporation in Wheeling, Illinois. This tank was last used by Sunnyside Corporation to store methylene chloride.