Violation Detail
Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 697658.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 04/29/2013 2
Initial Penalty: $7,000.00
Current Penalty: $4,200.00
Issuance Date: 04/12/2013
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 06/06/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2013 | $4,200.00 | 04/29/2013 | Serious | |
| Penalty | Z: Issued | 04/12/2013 | $7,000.00 | 04/29/2013 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(6)(i)(B): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: On or about October 18, 2013, the employer did not conduct an annual inspection from 2010 to present on the energy control procedures for cooker #1. Employees were exposed to caught-in and struck-by hazards.