Violation Detail
Standard Cited: 19100067 B02 Vehicle-mounted elevating and rotating work platforms.
Inspection Nr: 672618.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,050.00
Current Penalty: $3,582.00
Issuance Date: 04/05/2013
Nr Instances: 3
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0317300
Contest Date:
Final Order: 04/16/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/16/2013 | $3,582.00 | Serious | ||
| Penalty | Z: Issued | 04/05/2013 | $4,050.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.67(b)(2): A modified aerial lift was not certified by the manufacturer or NRTL as being at least as safe as the equipment was before modification: a) Greenville Place Apartments, Greenville, DE - Modifications to a Holan 819 Aerial Device exposed employees to potential equipment failure. On or about October 8, 2012. 1. Field attachable reusable fittings, used to repair damaged hydraulic hoses, were in use instead of fittings engineered for this particular device. 2. The lower boom's electrical insulating properties were modified as the fiberglass insert between the lower boom's knuckle & turntable ends, and the RTV sealed gaps connecting these ends were painted.