Violation Detail
Standard Cited: 19100178 M08 Powered industrial trucks.
Inspection Nr: 662098.015
Citation: 01003
Citation Type: Serious
Abatement Date: 04/19/2013 2
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 03/19/2013
Nr Instances: 1
Nr Exposed: 20
Related Event Code (REC): A
Gravity: 10
Report ID: 0627510
Contest Date:
Final Order: 04/03/2013
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/03/2013 | $7,000.00 | 04/19/2013 | Serious | |
| Penalty | Z: Issued | 03/19/2013 | $7,000.00 | 03/29/2013 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.178(m)(8): There was not sufficient headroom under overhead installations, lights, pipes, sprinkler system, etc. On September 27, 2012 and times prior to, employees were working under overhead energized power lines without sufficient headroom to safely operate rough terrain forklift. This condition exposed employees to electrical hazards.
Translate