Violation Detail
Standard Cited: 19100213 D01 Woodworking machinery requirements.
Inspection Nr: 604921.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 10/30/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 11/24/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/30/2012 | $2,800.00 | Serious | ||
Penalty | I: Informal Settlement | 10/19/2012 | $1,400.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: In the production area of M & S Custom Design and Services, Corp. located at 10318 NW 5th Street in Sunrise, Florida: A table saw being used by an employee performing wood working operations did not have a hood to completely enclose the portion of the blade above the table and above the material being cut, on or about August 30, 2012.