Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 526998.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 12/04/2012 2
Initial Penalty: $0.00
Current Penalty: $2,700.00
Issuance Date: 11/02/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 11/28/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/28/2012 | $2,700.00 | 12/04/2012 | Serious | |
| Penalty | Z: Issued | 11/02/2012 | $0.00 | 12/04/2012 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) On 6/16/12, an employee's fingers were injured when they were pinched off between a chain and sprocket on a lift truck. The lift truck was not shut down using established procedures. ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED