Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 470520.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 08/02/2012
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/26/2012
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A;R
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 08/15/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/15/2012 | $0.00 | 08/02/2012 | Serious | |
| Penalty | Z: Issued | 07/26/2012 | $0.00 | 08/02/2012 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) The employer did not ensure that employees, operating the IMR Low Pressure Casting Machine (BPC 155), properly isolated the hazardous energy from the manipulator prior to entering the danger area. This exposed employees to crushing and burn hazards.